| APPLICATION | LOADS | 400VA | 650VA | 800VA | 1400VA | 2.5KVA | 3.5KVA | 5KVA | 10KVA |
| DOMESTIC / RESIDENCE / NURSING / HOME / CLINICS |
Tube Light-40W CFL-20W Fan(ceiling) Television-21" CRT DVD Player Set top Box-DTH Music System Computer (14" CRT Monitor) Printer-Inkjet Refrigerator-165 ltr Mixer Water Heater-1000W AC - 1.5 ton |
2 3 2 |
3 5 2 1 1 |
4 6 3 1 1 1 1 1 |
7 9 5 2 1 1 1 2 1 1 1 |
10 15 7 2 1 1 1 3 2 1 1 1 |
15 20 10 2 1 1 1 4 2 1 1 1 |
10 15 5 3 1 1 1 5 1 1 1 1 1 |
10 15 5 3 1 1 1 5 1 1 1 1 2 |
| SOHO(SMALL OFFICE HOME OFFICE) |
Computer(14" CRT monitor) Tube Light-40W CFL Fan(ceiling) Printer - Inkjet Fax machine Scanner-Office AC-1.5ton |
1 2 4 1 1 1 1 |
3 2 4 2 1 1 1 |
5 4 8 3 2 1 1 |
7 7 12 5 2 1 1 |
10 9 15 5 3 1 1 1 |
15 12 18 5 3 1 1 2 | ||
| BANKS / RETAIL SHOP | Computer Tube Light CFL Fan Printer / POS Fax machine Scanner Cash counter machine AC |
2 8 15 4 2 |
3 12 20 5 3 1 1 3 |
4 15 25 4 4 1 2 4 |
5 20 30 4 5 1 2 5 1 |
8 30 40 4 8 1 3 8 2 | |||
| INTERNET / IT Education centers |
Computer Tube Light CFL Fan Printer Fax machine Scanner AC |
3 2 4 2 1 1 1 |
5 4 8 3 1 1 1 |
8 7 12 4 1 1 1 1 |
10 9 15 4 2 1 1 1 |
15 12 18 2 3 1 1 2 | |||
| Petrol Filling station | Tube Light CFL Computer Printer / POS PETROL Dispensers |
10 15 1 |
15 20 1 1 1 |
20 30 1 1 2 |
| Technical Specification - Input Parameters | |
| Input Voltage Range | 180V - 260V |
| Input Frequency | 50 Hz+_10Hz Window |
| Charging Power Factor | 0.85 |
| Phase | 1 Phase, 3 wire |
| Output Voltage | 230V+_7V |
| Output Power factor | 0.80 |
| Efficiency | >0.85% |
| Total Harmonic Direction | < 3% |
| Crest Factor | 3 : 1 |
| Change Overtime | < 10m Sec |
| Overload | Automatic 6 Retry |
| Surge Current Capacity | Up to 300% |
| Output Wave Form | Pure Sine Wave |
| Charging Voltage | 14.4 +_ 0.2 Per Battery |
| Trickle Voltage | 13.65V +_ 0.2V Per Battery |
| Low Battery Cut Off | 10V +_ 0.2 Per Battery |
| Charging Current | 10Amp +_ 2 Amp |
| Protection | |
| Over Load | Reverse Battery |
| Low Battery | Reverse Battery |
| Short Circuit | |
| Environmental Parameters | |
| Operating Temperature | 0-45 degree Celsius |
| Acoustic Noise at 1 Mtr | < 45 DB |
| Relative Humidity | Max 95%non - Condensing |
| Over Load | Input Voltage |
| Low Battery Short Circuit | Output Voltage |
| Mains MCB Trip | Input Frequency |
| Output Frequency | Battery Charging |
| Output Load% | Output Frequency |
| MODEL / RATING |
| ||||||||||||||||
| PHYSICAL |
|
| |||||||||||||||
| INPUT |
|
| |||||||||||||||
| OUTPUT |
|
| |||||||||||||||
| BATTERY CHARGING |
|
| |||||||||||||||
| TRANSFER TIME | Maximum | < 10 msec | |||||||||||||||
| PROTECTION | Full Protection | Overcharge, Short Circuit, Overload, Thermal shut down, Battery deep discharge | |||||||||||||||
| EFFICIENCY |
|
|
|||||||||||||||
| ENVIRONMENT | Operating Environment | -30 deg C to +95 deg C | |||||||||||||||